Remove middle side panel - see Gr. 41. Lower the door and window. Adjust gap ! to be parallel on bolt (1).
Note: It must be easy to press a lowered window further down with moderate thumb pressure on the upper edge of the glass when teh door is lowered.
Close the convertible top. Raise the door and door window. Window glass should seat uniformly in the seal everywhere. Adjust gap "S" when necessary. Distance S: 3 to 5 mm (0.118 to 0.197").
Window lift is adjusted with stop (2).
Turn or displace window laterally: Unscrew door guide rails in the door body. Adjust glass. Tighten window guide rails at top. Lower the door. Tighten window guide rails at bottom.
Note: A clamping prevention protector is switched on in zone B while raising the window.
The clamping prevention protector is switched off again in zone A. Distance A = approx. 4 mm (0.157") Distance B = approx. 200 mm (7.874").
If the window stops in zone B while raising the window or lowers further, check whether the window runs easily:
- Door window seal in area of cowl panel and top - Roller guides - Door lifting mechanism