REMOVING AND INSTALLING
AND CHECKING TANK
VENTING VALVE

Lift out plug.
Pull off hoses.
Lift out tank venting valve.

 
Connect vacuum hose (1) on the 8 mm
diameter adapter.
Supply 12 volts power to the tank
venting valve (2) with Special Tool
61 1 440 (2).

3216035 - click to zoom
 
Select multimeter funkction 21 on the
BMW Service Tester.
Adjust vacuum to 600 ± 100 mbar.
Then switch off.

3216036 - click to zoom
 
The pressure drop should not exceed
50 mbar during the testing time of
about 20 seconds.
The tank venting valve must be replaced,