REMOVING AND INSTALLING AND CHECKING TANK VENTING VALVE
Lift out plug. Pull off hoses. Lift out tank venting valve.
Connect vacuum hose (1) on the 8 mm diameter adapter. Supply 12 volts power to the tank venting valve (2) with Special Tool 61 1 440 (2).
Select multimeter funkction 21 on the BMW Service Tester. Adjust vacuum to 600 ± 100 mbar. Then switch off.
The pressure drop should not exceed 50 mbar during the testing time of about 20 seconds. The tank venting valve must be replaced, if the pressure drop exceeds 50 mbar.